Three Things You Can Do to Keep Your Facility Safe

NFPA70E-BoxChecking-Blog

May is Electrical Safety Month. Lucky for you, Thompson specializes in Electrical Safety. During this time, we want to inform you on three things that you can do to stay safe.

First, in order to keep your facility safe, it is important to have routine Thermal Imaging inspections completed. You should have this done by certified Thermographers that know and have experience on what they are doing. Once the Thermographers have looked at your equipment, you should then take a look at the digital and thermal images so you can see where the weak areas of your systems are. It is important to get those looked at and fixed so you can avoid any problems that could occur. Optimizing your equipment will make them more productive and more efficient.

Second, staying up-to-date with NFPA 70E and OSHA standards is also an important part of Electrical Safety. Falling below the line of the requirements can make your facility at risk for an accident. Training your employees on the standards will be important for their own safety as well. Your company can’t be very productive if you don’t have any knowledgeable employees around. By staying compliant with the requirements and standards of OSHA, you will keep your facility safe which in the long run will keep your employee’s safe while on the job.

Third, is getting an Arc Flash Risk Assessment completed. This form of Electrical safety is an important one as there can be many dangers that could occur from the result of an Arc Flash. Some of these include shrapnel wounds, high degree burns, blindness, and even death. You will need to have your equipment labeled in compliance with the OSHA and NFPA standards, this will make you aware of the protections that you need when servicing the pieces of equipment that are at risk. Having a risk assessment completed will inform you on what to do.

Don’t miss out on these opportunities to make your facilities better. Go to Thompson for all of your Electrical Safety needs. We have certified Thermographers, Trainers, and experts in Arc Flash to help you with any Electrical Safety needs. Contact us today. Our information is:

Phone: 844.321.3869

Email: help@thompsonspecialty.com

Website: www.thompsonspecialty.com

Keep Your Electrical Gear Clean and Tight

Electrical failures often can be avoided, and good preventative maintenance programs can help predict the imminent failure of equipment.  According to the Institute of Electrical and Electronics Engineers (IEEE), the failure rate of electrical equipment is three times higher when electrical preventive maintenance programs are not performed. This tells us that electrical failures can be avoided.

What should be included in an excellent electrical preventative maintenance program (EPM)? There are so many things that could be done such as: Equipment maintenance, cleaning, and thermal imaging.  However, where does one put the priority?  You have to consider the top causes of failure in electrical systems and these include: loose connections, improperly installed parts, defective/inadequate insulation, foreign objects causing short-circuiting, overloading inadequate capacity, and the accumulation of dust, dirt, and oil.  All things that can be prevented with routine and systemic electrical inspections.

Common in all these causes of electrical equipment failure is gear not being clean and well maintained.  Here are four things to keep in mind when developing an EPM program.

First, keep your gear clean. The buildup of dirt and metal debris in an electrical enclosure can cause arcing and arc flash explosions.  A second issue brought about by the accumulation of dirt and debris is an increase in heat and the temperature of the electrical equipment. Third, restricted airflow and an increase in the temperature of gear grossgearthompsondecreases the quality and usable life of the equipment.  Finally, a dirty environment also creates a hospitable home for rodents and vermin. We aren’t kidding, we really have found rodents in electrical gear. Dust is not your only enemy in dirty environments, so keep it clean.

Keep your gear tight. Loose connections are a major cause of electrical failures. More than 75% of the problems uncovered during routine thermal imaging inspections are loose connections. Thermography (infrared scanning) is a common way to identify areas that need repair but must be done while the gear is energized.  While the gear is off and being cleaned why not take an extra minute to check and tighten those loose connections?

If you have more questions or are looking for ideas and more information on best practice electrical preventative maintenance programs give the experts at Thompson Automation and Specialty Services a call today. They are ready and willing to help out in any way that they can.

Phone: 844.321.3869

Website: www.thompsonspecialty.com

Email: help@thompsonspecialty.com

Thermal Imaging is a Critical Piece of EPM

CoreGoodImage2

Electrical systems, just like mechanical systems, are prone to failure over time due to age, poor maintenance, and the stress of overuse.  People often wrongly assume that because electrical systems lack moving parts there is not a need for electrical preventative maintenance (EPM).  Nothing could be further from the truth.  While no one can claim to be perfect at identifying electrical problems before they arise, a good preventative maintenance program can help predict the imminent failure of equipment.   The early detection of problems can allow you to catch small issues before they become big ones.  A challenge faced, however, is the determination of what the right EPM program is.

While there is not a single EPM program or field of study that would catch all problems the most reliable and cost-effective inspection to have conducted is Thermal Imaging. Thermal Imaging is a non-contact, non-destructive technology proven effective in the early detection of imminent failure in an electrical and mechanical system. When properly conducted a Thermal Imaging inspection can identify “hot spots” or areas of a potential problem that necessitate further investigation and maintenance.  As you can see in this image, an area of concern is identified for further evaluation by the heat or temperature difference it is putting off against the ambient temperature.

If you have more questions or are looking for ideas and more information on Thermal Imaging or other best practice electrical preventative maintenance programs give the experts at Thompson Automation and Specialty Services a call today.  Given their 85+ years of experience as an electrical contractor, Thompson specializes in the development of custom electrical preventative maintenance programs for customers across the country.  Thompson understands the importance of keeping facilities safe, efficient and operating at peak performance and can custom tailor a program for you.